-40%

US Stock 3/12 Channel Dynamic ECG Holter 24/48 Hours EKG Recorder +Software

$ 157.87

Availability: 26 in stock
  • Return shipping will be paid by: Buyer
  • Item must be returned within: 60 Days
  • ECG & EKG Machine Type: Holter Monitor
  • All returns accepted: Returns Accepted
  • Condition: New
  • Restocking Fee: No
  • Brand: CONTEC
  • MPN: 69450401
  • Refund will be given as: Money back or replacement (buyer's choice)

    Description

    Model 1:TLC9803(5007) 3-channel 24h
    Introduction
    Dynamic ECG Systems adopt 3-lead, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.
    Function
    1)The recorder can real-time store ECG data for 24-hour.
    2)Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.
    3)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
    4)Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel.
    5)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
    6)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.
    7)With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.
    8)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
    9)With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.
    10)One-key print, convenient and fast to print the reports.
    11)Perfect case management function.
    12)The risk of sleep breath pause can be predicted by the unique "Sleep breath pause syndrome"analysis function.
    13)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
    14)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death
    Performance
    Lead: 3-lead
    Record time: 24-hour
    Power supply: two “AA” batteries
    Interface: USB2.0
    Calibration voltage: 1mV±5%
    Noise level: ≤30μV
    CMRR: ≥60dB
    Low-frequency characteristics: time constant≥3.2s
    Scan speed: 25mm/s±5%
    Polarizing voltage: ±300mV, sensitivity: ≤±10%
    Minimum measure signal: 50 µV p-p
    Accessories
    Lead cable (1 set)
    ECG electrode (1 bag)
    USB cable(1)
    Bag(1)
    User manual(1)
    Physical characteristic
    Dimension: 111mm(L) × 60mm(W) × 25mm(H)
    Weight: about 105g(without batteries)
    Model 2:TLC6000 12-channel 48h
    TLC6000 Dynamic ECG Systems contains recorder & analysis software. Recorder is an easy- to -use unit,
    which collects 12-lead ECG waveform synchronously and records continuously for 48 hours.
    Recorder features
    Compact design.
    OLED display.
    Function of event marking.
    Removable TF card(volume: up to 2GB).
    One "AAA" size battery can collect the ECG data of 48-hour.
    Ten electrodes synchronously collect the 12-lead ECG data.
    The features of software
    With 12 leads synchro analysis , QRS search can be more exactly
    There are more than 10 templates as atrial premature beat module, ventricular premature beat module,
    long interval module, atrial flutter module, atrial fibrillation module etc.and multiplicate User-defined templates
    could almost identify every kind of pathologic waveforms
    Flexible atrial fibrillation analysis, so that physicians can use full, segmented automatic, manual analysis of atrial fibrillation,
    make the analysis more quickly and accurately
    Powerful pacemaker analysis, on the AAI, VVI, DDD etc. all pacemaker analysis
    Any period of single lead or 12-leads ECG can be reviewed at any time with the function of fast waveform review and analysis
    Analysis of heart rate variability with short-range 5 minutes and long-range 1 hour and full analysis of heart rate variability
    A one-stop printing operation, report printing process is convenient and quick
    "Heart rate turbulence" analysis can predict the risk of death in patients with myocardial infarction
    "T Wave alternation" analysis is a important index on judging and preventing Arrhythmia
    The report has more reference value with the functions of VCG, VLP, TVCG and QTD analysis.
    Standard
    Lead mode: standard 12-lead
    Sampling accuracy: 12bit
    Recording time: 48h
    Scale voltage: 1mV±5%
    Standard Sensitivity: 10mm/mV±5%
    Noise level: ≤30μV
    CMRR: ≥60dB
    Low-frequency characteristics: Time constant≥3.2s
    Enduring polarization voltage:±300mV DC polarization voltage,sensitivity shift≤±10%
    Least measure signal: 50 µV p-p
    Product safety type: Type B applied part(Internally powered equipment)
    Accessories:
    ECG lead wires(12-Lead)
    ECG electrode(20 per bag)
    Micro sd Card Reader(1)
    Host bag(1)
    User manual(1)
    Physical Characteristic
    Dimension: 80.5mm(L) *59.5mm(W) *22mm (H)
    Weight: 61.5g
    Model 3:TLC5000 24h 12-channel
    TLC5000 Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.
    Function
    1)The recorder can real-time store ECG data for 24-hour.
    2)Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.
    3)Sync analysis for 12-lead, which ensures that QRS waveform can be found accurately, and no distortion.
    4)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
    5)Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel.
    6)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
    7)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.
    8)With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.
    9)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
    10)With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.
    11)One-key print, convenient and fast to print the reports.
    12)Perfect case management function.
    13)Abnormal ST can be analyzed according to the whole and event by the advanced ST segment analysis and total load of myocardial ischemia, which can help the doctors comprehensively judge myocardial ischemia.
    14)The risk of sleep breath pause can be predicted by the unique "Sleep breath pause syndrome"analysis function.
    15)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
    16)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death.
    17)With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.
    Performance
    Lead: standard 12-lead
    Record time: 24-hour
    Power supply: two “AA” batteries
    Interface: USB2.0
    Calibration voltage: 1mV±5%
    Noise level: ≤30μV
    CMRR: ≥60dB
    Low-frequency characteristics: time constant≥3.2s
    Scan speed: 25mm/s±5%
    Polarizing voltage: ±300mV, sensitivity: ≤±10%
    Minimum measure signal: 50 µV p-p
    Accessories
    Lead cable (1 set)
    ECG electrode (1 bag)
    USB cable(1)
    Bag(1)
    User manual(1)
    Physical characteristic
    Dimension: 111mm(L) × 60mm(W) × 25mm(H)
    Weight: about 105g(without batteries)
    Buy safe Products
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.If the item is subject to FDA regulation,We will verify your status as an authorized purchaser of this item before shipping of the item.If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health.
    The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE,TUV of Europe.The  Fingertip Pulse Oximeter that is FDA 510K Approved
    Only English User Manual,Please contact us if you need other language version.thank you