-40%
USA Digital 12-lead ECG/EKG Machine 12-channel Electrocardiograph Touch screen
$ 316.27
- Description
- Size Guide
Description
US Touch Screen Electrocardiograph ECG/EKG 12 channel/lead cardiograph ECG1200GShip from Illinois,united states. 2-5 days arrival.Offer free PC software and tow years warranty
Tips:
USA Buyer: ship from USA warehouse . Fast delivery (2-5 days) ;
Other Buyer : ship from China Warehouse. 1-2 weeks delivery.
Introduction
ECG1200G is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording
and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”,
multi-language interface, AC/DC, selecting rhythm lead, printing the trend chart and histogram of P-R interval, case database management.
Function
1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG
filter of ECG signal.
2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3)Multiply printing modes and formats, including auto 12x1, auto 6x2+1, auto 6x2+1_H, auto 6x2, auto 6x2_H, auto 3x4+1, auto 3x4+2, rhythm 12, rhythm 10, rhythm 8,
rhythm 6, manual, etc. Trend chart and histogram of P-R interval can be printed, waveform length printed can be adjusted, and with time print function, which meets
different requirements.
4)Paper speed: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.
5)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P
Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
6)Built-in memory stores up to 1000 cases, convenient for case review and statistic.
7)Multi-language(Turkish, French, Chinese, English, German, Kazakstan, Polish, Portuguese, Russian, Slovenian, Spanish and Ukrainian) interface and report.
8)In optimal DC state, up to 10-hour standby time, continuous print more than 3-hour, record up to 300 ECG waveform(commonly, it is 3s case), which meets the
requirements of visiting a patient at home and body examination.
Performance
Input mode: floating and defibrillation protection
Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
CMRR: >60dB, >100dB(add filter)
Time constant:≥ 3.2s
Patient leak current: <10μA
Calibration voltage: 1mV
Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
Noise level: ≤15μVp-p
Input circuit current: ≤50nA
Input impedance: ≥50MΩ
Sampling accuracy: 12-bit
Safety classification: class I, type CF and defibrillation-proof applied part
Recording mode: thermal printing system
Paper size: 210mm(W)×20m(L)
Sampling frequency: 1000Hz
EMG interference filter: 25Hz/35Hz (-3dB)
Power frequency filter: AC 50Hz/60Hz(-20dB)
Paper speed:
Auto: 25, 50mm/s, ±5%
Rhythm: 25, 50mm/s, ±5%
Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5%
Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing.
Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.
Manual record: set record according to record format, manually switching leads.
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
Power supply:
AC: 100V~240V(50/60Hz)
DC: 14.8V/3500mAh rechargeable lithium battery
Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V
Waterproof degree: IPX0
Working mode: continuous working
Accessories
Standard:
A lead cable
A limb electrode
A chest electrode
A thermal recording paper
A power cord
An earth wire
A user manual
ECG-Sync software+USB cable
Optional:
ECG electrode
Bag
Conductive paste
3G card
Wi-Fi card
Remote Operation Guide
Physical characteristic
Working environment
Temperature: 5℃~40℃
Relative humidity: 25%~95%(non-condensing)
Atmospheric pressure: 700hPa~1060hPa
Transport and storage environment
Temperature: -40℃~+55℃
Relative humidity: ≤95%
Atmospheric pressure: 500hPa~1060hPa
Dimension: 340mm(L) × 320mm(W) × 85mm(H)
Weigh: 3.2Kg
Certificate
CE&FDA
Buy Safe Product
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA
regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.
Shipment
1. We will ship the item within 48 hours after receiving your payment, please kindly leave your detail shipping address and telephone number, both are very important
for the shipment,thank you.
2.We will ship the machine directly from Illinois,united states. 2-5 days arrival.
3.We will upload the tracking number after shipment,you can search from both ebay and paypal.You can track online.
4. If you haven't received the item after 2 weeks of your payment, please contact me immediately!
Email/MSN:contecmandyathotmail.com
Terms Of Sale
1.If you have a defective item, you want to return or discount. Please contact us within 14 days from you receive the shipment.All return items must be returned with
its original packaging and accessories. Customer is responsible for shipping charges on returned items.
2.We will refund the money to you when we get the return items. Or replace item for you. We will deal with the refund in 2 business days when we get the info from
you.Please read our trade Policy before buy , if you don't agree our trade policy please don't buy it.
3.Sometimes there's some delay for the delivery of your package,Please kindly contact us for more information.Please don't open any cases nor return requests on both
ebay and paypal,and please don't leave me any negative nor neutral feedback on ebay.I will try my best to give you a satisfied solution.
Thanks for your purchase!
Only English User Manual,Please contact us if you need other language version.thank you